Technical

Firetec Device System Feature Reacton Tube Length Nozzle Tube Length Number of Fixed Nozzles Cylinder Capacities Pressure Options
CB
unit
melting bulb only n/a n/a n/a 500mls to 9 litres 4 to 35 bar B. F. G. H. J. K. L. M. Q. W. X. Y. Z.
CB
system
2 or more melt plugs n/a n/a n/a 1 litre to 9 litres 10 to 35 bar B. F. G. H. J. K. L. M. Q. R. W. X. Y.
CT melting tube only up to 4 x 8 metres n/a n/a 500mls to 40 litres 4 to 35 bar A. B. D. E. F. G. H. J. K. L. M. N. Q. R. U. V. W. X. Y. Z.
CTX No.7 melt tube up to 4 x 8 metres 1 to 30 metres 1-24 1 litre to 200 litres 4 to 35 bar

A. B. C. D. E. F. G. H. J. K. M. N. P. Q. R. S. T. U. V. W. X. Y. Z
nozzle supply tube 4 to 35 bar
CTX No.8 melt tube up to 4 x 8 metres 1 to 30 metres 1-24 1 litre to 200 litres 4 to 35 bar

A. B. C. D. E. F. G. H. J. K. L. M. N. P. Q. R. S. T. U. V. W. X. Y. Z
nozzle supply tube 6 to 300 bar
CTX No.9 melt tube up to 4 x 8 metres n/a n/a 1 litre to 200 litres 6 to 100 bar A. B. C. D. E. F. G. H. J. K. L. M. N. Q. R. T. U. V. W. X. Y. Z


All devices and systems can be installed, charged, and recharged on site.

All operate between - 40°C and + 160°C under appropriate conditions.

OPTIONS

NOTE: HIGH TEMPERATURE HEAT SENSITIVE Reacton 108 TUBE AVAILABLE AS OPTION FROM 1 MAY 2008

  • External recharge valve for easy pressure top up if necessary.
  • Most low pressure fire suppressants, e.g. powders, foams, and all low pressure Halon substitute gasses.
  • Most high pressure fire suppressant, e.g. CO2, water mist and all high pressure Halon substitute gasses.
  • Larger dimension Reacton tubing allowing lengths up to 4 x 12 metres
  • Full length Firetec® Chafegard, extra mechanical protection for Reacton tube.

  • N/C Passive acting switch to switch on remote audio and visual alarms.
  • N/O Passive acting switch to switch off ignition, power supply, fuel supply and other circuits.
  • Combined action N/O + N/C switch for multi functions.
  • Remote Firetec® LED system status display.
  • Cylinders configured for fixed horizontal, Layflat or inverted installation.

  • Cylinders configured for any-way-up variable use e.g. in rally car.
  • With Firetec® SP2 anti-corrosion protection.
  • Available with Firetec® plastic, nickel plated brass or stainless steel distribution manifolds.
  • Available with hydraulic, steel, PVC coated aluminium or PVC coated copper, distribution tubing.
  • Available with different temperature response characteristics.
  • Available with suppressant slow release device.
  • Available with manual activation device.
  • Available with remote activation device.
  • Available with manual deactivation device.
  • Available with remote deactivation device.
  • Available with military spec transport brackets.
  • Available pre-printed in customer’s logo.
  • Available with stainless steel cylinders.
  • Available in various formats including wiring loom protection and whole room flooding.
 
For further technical details contact Fire Monitoring Systems Ltd.

Email: technical@FiretecUK.com

CTX Firetec

CT in major item of contractor's plant

CT in car engine compartment

Firetec

CT in Contractor's Plant

CT in heavy mining machinery

CT in central London

Firetec